Ion exchange (IEX) chromatography is a very effective method for the separation and purification of biomolecule. The method mainly relies on the interaction between positive and negative charges, and uses the charge properties and differences of different biological molecules under specific conditions to separate them. It has the characteristics of high load, good resolution, controllable condition and easy scale-up. It has been widely used in medicine, chemical industry, metallurgy, food and other fields.
IEX resin is composed of three parts: (1) Cross-linked agarose matrix, that has the characteristics of porous, hydrophilic and good chemical stability. (2)Functional groups fixed to the matrix, which are electrically charged groups, determine the properties of the IEX resin. (3)An ion (called an equilibrium ion) that has an opposite charge to the functional group and can be reversibly bound to the functional group.
DEAE Bestarose FF (Fast Flow) is a weak anion exchange resin formed by coupling diethylaminoethyl to high-flow agarose microspheres.
Appearance |
White slurry |
Matrix |
Cross-linked agarose |
Functional Group |
Diethylaminoethyl |
Particle size+ |
45~165μm |
Ionic capacity |
110-160μmol /mL packed resin |
Max. pressure |
0.3MPa |
Pressure flow velocity++ |
≥300cm/h(0.1MPa ,BXK50/30,H=15cm ,20℃,0.1M NaCl) |
Chemical stability |
Stable in common aqueous buffers: 1M NaOH+++,1M HAC+++, 6M GuHCl,8M Urea, 70% ethanol,30% Isopropyl alcohol, 20% ethanol, 2%Benzyl alcohol |
pH stability |
2~14(CIP), 2~12 (Working) |
Operating temperature |
Operating temperature:2~40℃, do not freeze |
Storage++++ |
2~30℃, 20%ethanol or 2% benzyl alcohol |
Recommend flow velocity |
60~300cm/h |
Avoid |
Avoid contact with oxidizing agents, cationic detergents. Avoid long time exposures (1 week, 20℃) to pH <4. |
+Particle size is normally distributed, and particles within this range account for more than 95% of the total.
++ The pressure flow velocity describes the relationship between pressure and flow under the set circumstances. The pressure given shall not be taken as the maximum pressure of the resin. Pressure flow velocity is shown in Fig 1.
+++1M NaOH and 1M HAc only be used for cleaning.
++++2% benzyl alcohol is only used for international transport or special requirements from customer.
Product |
Cat. No. |
Pack size |
DEAE Bestarose FF |
AI0031 |
25mL |
AI0032 |
100mL |
|
AI0033 |
500mL |
|
AI0034 |
1L |
|
AI0035 |
5L |
|
AI0036 |
10L |
|
AI0037 |
20L |
|
AI0038 |
40L |
Prepacked columns |
Cat. No. |
Pack size |
EzFast DEAE FF |
EI00321 |
1×1mL |
EI011 |
5×1mL |
|
EI202303 |
1×5mL |
|
EI012 |
5×5mL |
|
EzScreen DEAE FF |
EI00325 |
1×4.6mL |
EI00335 |
5×4.6mL |
|
EzLoad 16/10 DEAE FF |
EI014 |
1 pcs |
EzLoad 26/10 DEAE FF |
EI015 |
1 pcs |
EzLoad 16/10 DEAE FF(Double stigma head) |
EI053 |
1 pcs |